1.窗簾板的涂層脫落并生銹。簾板有明顯的壓坑、凹凸和透孔。濟(jì)南卷簾門是一個(gè)完整的消防產(chǎn)品。如果簾板有問(wèn)題,將直接影響卷簾式卷簾門的耐火極限指標(biāo)。
1. The coating of curtain board falls off and rusts. The curtain plate has obvious indentation, concave-convex and through-hole. Jinan rolling shutter door is a complete fire protection product. If there is a problem with the shutter, it will directly affect the fire endurance index of the roller shutter door.
2.導(dǎo)軌變形或落地窗簾卡不平穩(wěn)。卷簾門通常沿著導(dǎo)軌移動(dòng)。如果導(dǎo)軌扭曲或斷裂,卷簾門無(wú)法移動(dòng)到指定位置,無(wú)法達(dá)到分隔的效果。
2. The guide rail is deformed or the floor curtain card is unstable. The roller shutter usually moves along the guide rail. If the guide rail is twisted or broken, the roller shutter door cannot move to the specified position and cannot achieve the separation effect.
3.卷簾的上下限位置失效或限位線連接錯(cuò)誤。這種情況經(jīng)常發(fā)生在中庭的卷簾上。由于中庭的卷簾有時(shí)安裝在上層走道的外面,導(dǎo)致卷簾下的樓層無(wú)法關(guān)閉,大的縫隙漏出來(lái),無(wú)法實(shí)現(xiàn)上下樓層的分隔。
3. The upper and lower limit positions of the roller shutter are invalid or the limit line is connected incorrectly. This often happens on the rolling curtain of the atrium. Because the roll-up curtain of the atrium is sometimes installed outside the upper walkway, the floors under the roll-up curtain cannot be closed, large gaps leak out, and the separation between the upper and lower floors cannot be achieved.
4、操作不動(dòng)作,按鈕觸點(diǎn)燒壞,線路受阻或簾板只上下、相位不對(duì)、上下顛倒。一些卷簾門安裝在普通走道或疏散走道上,通過(guò)這些走道需要疏散人員,這將不可避免地需要一個(gè)裝置來(lái)手動(dòng)控制卷簾門的移動(dòng)。如果設(shè)備損壞,將會(huì)帶來(lái)不必要的傷亡和損失。
4. The operation does not work, the button contact is burnt, the line is blocked, or the curtain is only up and down, the phase is wrong, and the up and down are reversed. Some roller shutter doors are installed on common walkways or evacuation walkways, through which people need to evacuate, which will inevitably require a device to manually control the movement of roller shutter doors. If the equipment is damaged, it will cause unnecessary casualties and losses.
卷簾門消防驗(yàn)收過(guò)程中可能遇到的問(wèn)題現(xiàn)在就講解了四個(gè)方面,您有怎樣的需求就來(lái)我們網(wǎng)站http://ifxf.cn咨詢吧!
The problems that may be encountered in the fire inspection and acceptance process of rolling shutter doors are explained in four aspects now. If you have any requirements, please come to our website http://ifxf.cn Ask!
閱讀/ Recommended reading
- 如何延長(zhǎng)卷閘門的壽命 2024-11-06
- 重視卷簾門門口堆物問(wèn)題 2024-11-06
- 快速卷簾門介紹與快速卷簾門材料說(shuō)明 2024-10-26
- 濟(jì)南卷簾門廠:卷簾門安裝施工工藝詳解 2024-10-14
- 濟(jì)南卷簾門安裝秘籍,讓家居更有面子 2024-09-21
- 濟(jì)南遙控卷簾門:我來(lái)教你——卷閘門遙控器遇到故障怎么辦? 2024-08-28
- 濟(jì)南卷簾門:卷簾門(不銹鋼款) 2024-07-25
- 濟(jì)南卷簾門的故障維修與更換卷簾門注意事項(xiàng) 2024-07-19
濟(jì)南卷簾門:斷掉一片后的處理方法,你學(xué)會(huì)了嗎?
2024-11-19
檢查斷裂原因:需要檢查卷簾門斷裂的具體原因??赡苁怯捎谳S管斷裂、螺栓松脫、脫鉤脫軌或線路問(wèn)題等。如果是軸管斷裂或螺栓松脫,需要更換相同規(guī)格的軸管或螺栓?! heck th...